Euchner Vietnam, MGB-L0-APA-AA6A1-S3-R-110546 (ORDER NO. 110546),  Đại lý chính hãng Euchner Tại VietNam

 

MGB-L0-APA-AA6A1-S3-R-110546 (ORDER NO. 110546)

 

Interlocking module MGB-L0-APA.., with 3 pushbuttons, incl. label carrier, M12 for enabling switch

  • Interlocking (without guard locking)
  • 3 pushbuttons (illuminated, wh, ye, bu)
  • incl. adhesive labels
  • With cable entry
  • With plug connector M12 for enabling switch
  • Unicode

 

Controls and indicators

Assignment diagram L1
Item Extras Color Designation1 Number LED Version Slide-in label Switching element Einlegeschild Anmerkung
2   white       Illuminated pushbutton   1NO  
3   yellow       Illuminated pushbutton   1NO  
4   blue       Illuminated pushbutton   1NO  
 

Electrical connection ratings

Connection cross-section  
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 0.25 ... 1.5 mm²
(rigid/flexible) 0.13 ... 1.5 mm² 
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0.25 ... 0.75 mm²
Degree of contamination (external, according to EN 60947-1) 3
Discrepancy time  
between FO1A and FO1B max. 10 ms
Rated impulse withstand voltage Uimp 1.5 kV
Rated insulation voltage Ui 30 V
Risk time according to EN 60947-5-3 max. 350 ms
Safety class III
Transponder coding Unicode
Utilization category  
DC-13 24V 200mA 
  Controls and indicators
Breaking capacity max. 0.25 W
LED power supply 24 V DC
Switching current 1 ... 10 mA
Switching voltage UA V
  Monitoring outputs OD, OT, OL, OI
Output current max. 50 mA
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC 
  Safety outputs FO1A, FO1B
Output current  
per safety output FO1A / FO1B 1 ... 200 mA
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B HIGH UB-2V ... UB V DC 
UFO1A /UFO1B LOW 0 ... 1 V DC
Test pulse interval min. 100 ms
Test pulses max. 0.3 ms
  Power supply UA
Current consumption  
IUA max. 10 mA 
Operating voltage DC  
UA 24 V DC -15% ... +10% 
  Power supply UB
Current consumption  
IUB max. 80 mA 
Operating voltage DC  
UB 24 V DC -15% ... +10% 

Mechanical values and environment

Ambient temperature  
at UB = 24V DC -20 ... +55 °C
Connection  
  Cable entries M20x1.5
  Plug connector SFF5 
Degree of protection IP65
Installation orientation Door hinge DIN right
Material  
Housing Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Mechanical life  
  1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Switching frequency 0.25 Hz

Reliability values according to EN ISO 13849-1

Mission time 20 y
  Monitoring of the guard position
Category 4
Performance Level PL e
PFHd 3.7 x 10-9

Miscellaneous

Product version number V3.0.0
Slide-in label  
Anzahl Beschriftung Anmerkung
3   ohne Aufschrift
  Automatik Start  
  Störung Quittieren  
  Failure Reset  
  Automatic Start  
  Zutritt Anforderung  
  Access Request
MGB-L0-APA-AA6A1-S3-R-110546 (Order no. 110546)