100% Germany Origin
|
Bronkhorst Vietnam
|
Model key : F-111AC-50K-AGD-22-V
Mass Flowmeter
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : N2 (Nitrogen)
Flow range : 1...50 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 2 bar (g)
Temperature : 20...35 °C (calibrated for 27.5 °C)
Seals : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/4" OD compression type
Output signal : RS-232 0...100 % (0...5 Vdc)
Setpoint : RS-232 0...100 % (0...5 Vdc)
Power supply : +15...24 Vdc
|
100% Germany Origin
|
Bronkhorst Vietnam
|
Additional calculated curve for
Fluid : N2 (Nitrogen)
Flow range : 3.454E-01...17.27 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 2 bar (g)
Temperature : 20...35 °C (calibrated for 27.5 °C)
Conversion table : 11 points
Stored in instrument of pos 001 as Fluid 2
|
100% Germany Origin
|
Bronkhorst Vietnam
|
Swagelok portconnector 1/4x1/4
Swagelok portconnector 1/4"x1/4"
|
100% Germany Origin
|
Bronkhorst Vietnam
|
F-004AC Control valve
Model key : F-004AC-LUU-21-V
Ingress Protection : IP-40
Fluid : N2 (Nitrogen)
Flow range : 1...50 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : Fixed
Temperature : 20...35 °C
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/4" OD compression type
Outlet connection : 1/8" OD compression type
|
100% Germany Origin
|
Bronkhorst Vietnam
|
F-201CV/F-211CV Mass Flow Controller
Model key : F-201CV-500-AGD-11-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : N2 (Nitrogen)
Flow range : 6.908E-03...3.454E-01 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS(At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : 0.30 mm
Temperature : 20 °C
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/8" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc
|
100% Germany Origin
|
Bronkhorst Vietnam
|
Additional calculated curve for
Fluid : N2 (Nitrogen)
Flow range : 3.412E-03...1.706E-01 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Temperature : 20 °C
Conversion table : 11 points
Stored in instrument of pos 004 as Fluid 2
|
100% Germany Origin
|
Bronkhorst Vietnam
|
F-201AV/F-211AV Mass Flow Controller
Model key : F-201AV-50K-AGD-11-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : H2 (Hydrogen)
Flow range : 1...50 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : 1.50 mm
Temperature : 25...35 °C (calibrated for 30 °C)
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/8" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc
|
100% Germany Origin
|
Bronkhorst Vietnam
|
Additional calculated curve for
Fluid : H2 (Hydrogen)
Flow range : 3.524E-01...17.62 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Conversion table : 11 points
Stored in instrument of pos 005 as Fluid 2
|
100% Germany Origin
|
Bronkhorst Vietnam
|
F-201CV/F-211CV Mass Flow Controller
Model key : F-201CV-500-AGD-11-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : H2 (Hydrogen)
Flow range : 0.007...3.524E-01 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : 0.14 mm
Temperature : 25...35 °C (calibrated for 30 °C)
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/8" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc
|
100% Germany Origin
|
Bronkhorst Vietnam
|
Additional calculated curve for
Fluid : H2 (Hydrogen)
Flow range : 3.48E-03...0.174 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Conversion table : 11 points
Stored in instrument of pos 006 as Fluid 2
|
100% Germany Origin
|
Bronkhorst Vietnam
|
F-111AC Mass Flow Meter
Model key : F-111AC-50K-AGD-12-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : CO (Carbon monoxide)
Flow range : 1...50 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 2 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Seals : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/4" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc
|
100% Germany Origin
|
Bronkhorst Vietnam
|
Additional calculated curve for
Fluid : CO (Carbon monoxide)
Flow range : 3.448E-01...17.24 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 2 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Conversion table : 11 points
Stored in instrument of pos 008 as Fluid 2
|
100% Germany Origin
|
Bronkhorst Vietnam
|
Swagelok portconnector 1/4x1/4
Swagelok portconnector 1/4"x1/4"
|
100% Germany Origin
|
Bronkhorst Vietnam
|
F-004AC Control valve
Model key : F-004AC-LUU-21-V
Ingress Protection : IP-40
Fluid : CO (Carbon monoxide)
Flow range : 1...50 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : Fixed
Temperature : 25...35 °C
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/4" OD compression type
Outlet connection : 1/8" OD compression type
|
100% Germany Origin
|
Bronkhorst Vietnam
|
F-201CV/F-211CV Mass Flow Controller
Model key : F-201CV-500-AGD-11-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : CO (Carbon monoxide)
Flow range : 6.896E-03...3.448E-01 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : 0.30 mm
Temperature : 25...35 °C (calibrated for 30 °C)
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/8" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc
|
100% Germany Origin
|
Bronkhorst Vietnam
|
Additional calculated curve for
Fluid : CO (Carbon monoxide)
Flow range : 3.406E-03...1.703E-01 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Conversion table : 11 points
Stored in instrument of pos 007 as Fluid 2
|
100% Germany Origin
|
Bronkhorst Vietnam
|
F-201CV/F-211CV Mass Flow Controller
Model key : F-201CV-500-AGD-11-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : Air
Flow range : 6.912E-03...3.456E-01 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS
(At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : 0.30 mm
Temperature : 25...35 °C (calibrated for 30 °C)
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/8" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc
|