100% Germany Origin
|
DOLD Vietnam
|
Art number: 0054050
Relay MK7850N.82/200 AC/DC12-240V
|
100% Germany Origin
|
DOLD Vietnam
|
Art number: 0018638
Relay MK8804.13 AC/DC230-240V
|
100% UKA Origin
|
Kempston Controls Vietnam
|
Code: CFK18
CFK18 FUSE BOX CONTRACTOR PACK: 180PCS 5X20 FAST GLASS + PLUG TOP FUSES
|
100% Germany Origin
|
Imada - Hans-Schmidt Vietnam
|
Code: HV-500N
Test Stands
|
100% USA/Singapore Origin
|
Rosemount Vietnam
|
Model: 2051CD3A22A1AB4M5
Diff Pressure Transmiter (Range : -2.5 bar đến 2.5 bar)
|
100% USA/Singapore Origin
|
Rosemount Vietnam
|
Model: 2088G4S22A1B4Q4
Smart Pressure Transmitter (Range : -1.01 to 275.8 bar)
|
100% USA/Singapore Origin
|
Rosemount Vietnam
|
Model: 2088G3S22A1B4Q4
Smart Pressure Transmitter (Range : -1.01 to 55.2 bar)
|
100% USA Origin
|
Watlow Vietnam
|
Model: 010100C1-4001B
Heater; HTR-WIREWOUND ELEMENT
|
100% Korea Origin
|
WISE Vietnam
|
Model: P1103A4DCI02850
Pressure Gauge Range: 0-0.2MPa
|
100% Germany Origin
|
Balluff Vietnam
|
BES0054
BES M12MI-NSC20B-S04G Inductive Sensors
|
100% Germany Origin
|
Balluff Vietnam
|
BGL0016
BGL 30A-001-S49 Photoelectric Sensors
|
100% Germany Origin
|
Balluff Vietnam
|
BCC081Y
BCC M313-0000-10-001-VX8334-030 Single-Ended Cordsets
|
100% Germany Origin
|
Balluff Vietnam
|
BES011C
Description: BES 516-383-E4-C-03 Inductive Sensors
|
100% Germany Origin
|
Balluff Vietnam
|
BES0161
BES 516-113-S4-C Inductive Sensors
|
100% Germany Origin
|
Balluff Vietnam
|
BES017T
BES 516-300-S166-03 Inductive Sensors
|
100% Germany Origin
|
WERMA Vietnam
|
Code: 431.100.60
LED Siren BM 32 tne 115-230VAC RD
|
100% Germany Origin
|
WERMA Vietnam
|
Code: 423.110.68
Buzzer/Flash WM Contin/pulse 230VAC RD
|
100% Germany Origin
|
WERMA Vietnam
|
Code: 582.052.68
Signal horn WM Contin. tone 230VAC GY
|
100% Germany Origin
|
WERMA Vietnam
|
Code: 584.000.68
Signal horn WM Contin. tone 230VAC GY
|
100% USA Origin
|
Delco Remy Vietnam
|
Code: 8200330
|
100% Taiwan/Chian Origin
|
Liming Vietnam
|
Model: PB120-10
Gear Box; Note: báo giá theo nameplate sales gửi
|
100% Germany Origin
|
Bernstein Vietnam
|
Code: 6507956001
KCB-E68PS/010-KLP2(A) Capacitive Proximity Switch
|
100% Germany Origin
|
DOLD Vietnam
|
Art number: 0044769
Switches Unlimited BA9043 3/N AC50-400HZ 400/690V
|
100% Italy Origin
|
Servomech Vietnam
|
Cod Prod: 02.030/5431 rev.0
BSA 30 BS20x10 RV2 C800 FO FI RPT90°; Vers.4 IEC63B14
prepared for encoder SICK AFM60E-BDLA004096 H-LH
AC 3 PH MOTOR 0,37kW 4poli 230/400V 50HZ; SEP WIRED BRAKE
SPEC SHAFT + FLANGE; TERMIC PROTECTION; MANUAL HAND REALSE; TROPICALIZED IP55 F (n.s.15.0469.03782-03783)
|
100% USA Origin
|
Allen Bradley Vietnam
|
Model: 1734-IE4C
I/O Module
|
100% Germany Origin
|
Balluff Vietnam
|
BTL17NN
Replaced by: BTL7-P511-M0100-B-S32
(BTL0156 Code: BTL5-P1-M0100-B-S32)
|
100% Switzerland Origin
|
Tantronics Vietnam
|
Part No.: 01-92-34522-A
Programming Analys 2016net with 13 MP
|
100% Switzerland Origin
|
Tantronics Vietnam
|
Replaced by: 00-92-35200-A
Analys 2016net
Analyser with up to 16 measuring points for the measurement of toxic or explosive gas or oxygen with a pump-bypass system.Indication of the gas concentration and the alarm status. To actuate the pre sucktion pump block. To actuate the solenoid valve block with separately pre suck and sample drawing. The system can be adapted to all customized requirements, simply with the password protected menu structure. The configuration of the alarm organization is very simply realized with the integrated alarm matrix.
Technical Data:
Type of device: Analys 2016net; Power Supply: 24V DC; Max. Consumption: 25W; Temperature Range: -20°C to +50°C (short time 60°C); Analog-Output: 1x4-20mA (max. 250 ohms); Digital-Output: 4 Logic Signal for Alarm 1 to 4; 1 Logic Signal for Sensor Fault; 1 Logic Signal for Calibration Mode *; 1 Logic Signal for Calibration Status
1 Logic Signal for Maintenance Alarm; to activate the Solenoid Valve Unit; to activate the Presuction Pump Block; Network: TCP/IP RS232C, CAN Bus (in preparation); Remote Control: with TCP/IP
Data Pick Out: with FTP; Event Recorder: for max. 4000 Events
Temperature Recorder: for max. 4000 Events
* Note dew point of sampling Technical Data IR-Sensor:
Type of Gas: Methane CH4; Measuring Principle: ND-Infrared Detector; Measuring Range: 0-100% LEL; Reaction Time T90: < 10 seconds; Accuracy: 2% FS; Stability: < ± 1% / Month; Zero-Drift: < ± 1% / Month; Temperature Range: -20°C to +50°C (short time 60°C)
Relative Humidity: < 99% RH; Warm up Time: 1 hour
Electrical Connections:
Power Supply: 3 pole Plug; Interface: 2x37 pole Plug; RS232C: 1x9 pole Plug; CAN: 1x9 pole Plug; TCP/IP: 1x RJ45; Remote Control: with Web Interface; Housing Type: 19'' inch rack version; Painting: RAL 7035/5002; Type of Protection: IP30
Note: Analys 2000 that is replaced and 100% compatible with the new Analys 2016net (Tanguard 2000)
|
100% Switzerland Origin
|
Tantronics Vietnam
|
Part No.: 01-91-34496-A
Programming TanGuard 2016net 1 for GT13E (KKS218 replacement for Tanguard 2008); Sensor 1 Exhaust Air Duct Sensor 1 KKS CYQ01CQ212; Sensor 2 Ignitiongas Sensor KKS CYQ01CQ281
|
100% Switzerland Origin
|
Tantronics Vietnam
|
Part No.: 01-91-34523-A
Programming Tanguard 2016net 2 GT13E2 (KKS219 replacement for Tanguard 2008); Sensor 1 Exhaust Air Duct Sensor 2 KKS CYQ01CQ213
|
100% Switzerland Origin
|
Tantronics Vietnam
|
Part No.: 00-91-35100-A
TanGuard 2016net
TanGuard 2016net is the modern microprocessor based gas warning device to monitoring and alerting of toxic and explosive gases and steams for up toeight measuring points into compact 19'' inch rack.The system can be udapted to all customized requirements simply with the password protected menu structure. The attitudes for the attached gas transmitters are made with the internal keyboard. The configuration of the alarm organization is verysimply realized with the integrated alarm matrix
Technical Data:
Type of Device: TanGuard 2016net; Power Supply: 24V DC; Max. Consumption: depending on Sensor Type max. 50W; Temperature Range: -0°C to +50°C (short time 60°C); Analog-Output: 8x4-20mA (max. 250 ohms); Digital-Output: 8x3 Logic Signal for Alarm 1 to 4; 1 Logic Signal for Sensor Fault; 1 Logic Signal for Calibration Mode* 1 Logic Signal for Calibration Status; 1 Logic Signal for Maintenance Alarm; Network: TCP/IP RS232C, CAN Bus (in preparation); Remote Control: with TCP/IP; Data Pick Out: with FTP; Event Recorder: for max. 4000 Events; Temperature Recorder: for max 4000 Events
Electrical Connections:
Power Supply: 3 pole Plug; Interface: 2x37 pole Plug; RS232C: 1x9 pole Plug; CAN: 1x9 pole Plug; TCP/IP: 1x RJ45; Remote Control: with Web Interface; Housing Type: 19'' inch rack version; Painting: RAL 7035/5002; Type of Protection: IP30
|