100% Germany Origin

Leuze Vietnam

Part number: 50127061
Code: HT46CI/4P-M12
Diffuse sensor with background suppression, Operating range limit 0.005 ... 3 m, LED, Infrared, 10-30VDC, 1 x PNP Light switching + 1 x PNP Dark switching, M12-4pin connector, Multiturn potentiometer, -40 ... 60 °C, IP 67/IP 69K
HRT 46B/66-S12 Obsolete, replacement options are HT46CI/4P-M12 and HT46CI/2N-M12

100% Germany Origin

Leuze Vietnam

Part number: 50129671
Code: HT46CI/2N-M12
Diffuse sensor with background suppression, Operating range limit 0.005 ... 3 m, LED, Infrared, 10-30VDC, 1 x NPN Light switching + 1 x NPN Dark switching, M12 -4pin connector, Multiturn potentiometer, -40 ... 60 °C, IP 67/IP 69K
HRT 46B/66-S12 Obsolete, replacement options are HT46CI/4P-M12 and HT46CI/2N-M12

100% Germany Origin

Leuze Vietnam

Part number: 50127012
Code: PRK46C/4P-M12
Polarized retro-reflective photoelectric sensor, range: 0.1 ... 30 m, 10-30 VDC, 2 x PNP outputs, M12 4Pin connector, -40 ... 60 °C, IP67/IP69K
PRK 46B/66-S12 Obsolete, replacement options are PRK46C/4P-M12 and PRK46C/2N-M12

100% Germany Origin

Leuze Vietnam

Part number: 50127018
Code: PRK46C/2N-M12
Polarized retro-reflective photoelectric sensor, range: 0.1 ... 30 m, 10-30 VDC, 2 x NPN outputs, M12 4Pin connector, -40 ... 60 °C, IP67/IP69K
PRK 46B/66-S12 Obsolete, replacement options are PRK46C/4P-M12 and PRK46C/2N-M12

100% Germany Origin

Leuze Vietnam

Part number: 50127012
Code: PRK46C/4P-M12
Polarized retro-reflective photoelectric sensor, range: 0.1 ... 30 m, 10-30 VDC, 2 x PNP outputs, M12 4Pin connector, -40 ... 60 °C, IP67/IP69K

100% USA Origin

Allen Bradley Vietnam

Model: 1756-IF16
Module 1756-IF16

100% USA Origin

Allen Bradley Vietnam

Model: 1756-IB32
Module 1756-IF17

100% USA Origin

Allen Bradley Vietnam

Model: 1756-OB32
Module 1756-IF18

100% USA Origin

Allen Bradley Vietnam

Model: 1756-PA72
Module 1756-IF19

100% USA Origin

Allen Bradley Vietnam

Model: 1756-CNBR
Module 1756-IF20

100% China Origin

INVT Vietnam

Model: CHF100A7R5G/011P-4-7.5kW (CHF 100A 7R5G/011P-4)
Inverter 7.5kW

100% Europe/China Origin

Festo Vietnam

Model: DSR-40-180-P
Semi-Rotary Drive; Part No: 13467

100% Europe/China Origin

Festo Vietnam

Replaced by: DSBC-100-400-PPVA-N3
(DNC-100-400-PPV-A) Cylinder

100% Europe/China Origin

Festo Vietnam

Model: DSBC-80-160-PPVA-N3
Cylinder

100% Europe/China Origin

Festo Vietnam

Replaced by: DSBC-32-40-PPVA-N3
(DNC32-40-PPV-A) Cylinder

100% Europe/China Origin

Festo Vietnam

Model: ADVU-50-20-P-A
Cylinder

100% Europe/China Origin

Festo Vietnam

Replaced by: DSBG-63-160-PPVA-N3
(DNG-63-160-PPV-A) Cylinder

100% Europe/China Origin

Festo Vietnam

Replaced by: LR-1/2-D-7-MIDI-MPA
(LR-1/2-D-7-MIDI) Pressure Regulator

100% Europe/China Origin

Festo Vietnam

Model: LF-1/2-D-5M-MIDI
Filter

100% Europe/China Origin

Festo Vietnam

Model: FEN-25-54-KF
Guide Unit

100% Germany Origin

Ebm-Papst Vietnam

Model: DV4650-470 (DV 4650-470)
ORDER PANEL COOLER FAN-EBMPAPST PANEL XIAL FAN
POWER: 230VAC-50HZ, 110MA, 2650r/min, 17.7W/5.3W

100% Europe Origin

ABB Vietnam

Type: APBU-44C (4CH)
PPCS Branching Unit

100% Japan Origin

CKD Vietnam

Model: SW-TOH
Cylinder Sensor

100% USA Origin

OMEGA Vietnam

HMPW-NI-M
Mini High Temperature Connector Pink

100% USA Origin

OMEGA Vietnam

HMPW-NI-F
Mini High Temperature Connector Pink

100% USA Origin

OMEGA Vietnam

HMPW-R/S-M
Mini High Temperature Connector Green

100% USA Origin

OMEGA Vietnam

HMPW-R/S-F
Mini High Temperature Connector Green

100% USA Origin

OMEGA Vietnam

HMPW-K-M
Mini High Temperature Connector Yellow

100% USA Origin

OMEGA Vietnam

HMPW-K-F
Mini High Temperature Connector Yellow

100% USA Origin

OMEGA Vietnam

HMPW-J-M
Mini High Temperature Connector Black

100% USA Origin

OMEGA Vietnam

HMPW-J-F
Mini High Temperature Connector Black

100% Germany Origin

Rexroth Vietnam

Code: 0820022990
Valve

100% Germany Origin

Rexroth Vietnam

Code: 1824210235
Coil

100% USA Origin

GF Vietnam

Model: P525-2S
Flow Sensors

100% Germany Origin

Turck

Correct Model: BIM-NST-AP6X-H1141
(BIMNSTAP6XH114) Sensor

100% Germany Origin

IFM

Model: SA3010
SAD18BBDFRKG/W/US-100-IPF

100% Germany Origin

SIKO

Model: MKS320-0312

100% Germany Origin

SIKO

Model: MRI01-0001

100% UK Origin

Multitek Vietnam

Model: M100-WT9-100/5A
(M100-WT9) Transducer Aux 230VAC

100% UK Origin

Multitek Vietnam

Model: M100-WT9-200/5A
(M100-WT9) Transducer Aux 230VAC

100% Taiwan Origin

DECO Vietnam

Model: VP531A-4FR
Micro Switch

100% Germany Origin

Balluff Vietnam

BOS01Y1
BOS 12M-PO-PR10-S4 Photoelectric Sensors

100% Germany Origin

Balluff Vietnam

BES01C7
BES 516-325-G-S4-C Inductive Sensors

100% Germany Origin

Balluff Vietnam

BES00EF
BES M12ME-PSC40B-S04G-003 Inductive Sensors

100% Germany Origin

Balluff Vietnam

BES01ZN
BES M12MI-PSH80B-S04G Inductive Sensors

100% Taiwan Origin

MOXA Vietnam

Model: EDS-205A-T

100% Germany Origin

Baumuller Vietnam

Item No.: 00398032
Servomotor; DSD036L-65U4554 0276/0850x1 – PB B04 SKS36
Drawing M0360037A; Torque: M =2.2/1.8 Nm; Speed” n=3000/4500 1/min; Power: P = 700/850 W; Current: I=2.75/2.3 A; Voltage: 540 VDC; Protection Class: Housing IP65, Shaft IP44; With encoder SinCos SRS 50; With temperature Sensor KTY 84-130; With Brake 24V/ 4.0Nm

100% Switzerland Origin

Tantronics Vietnam

Part No.: 01-92-34522-A
Programming Analys 2016net with 13 MP

100% Switzerland Origin

Tantronics Vietnam

Replaced by: 00-92-35200-A
Analys 2016net

Analyser with up to 16 measuring points for the measurement of toxic or explosive gas or oxygen with a pump-bypass system.Indication of the gas concentration and the alarm status. To actuate the pre sucktion pump block. To actuate the solenoid valve block with separately pre suck and sample drawing. The system can be adapted to all customized requirements, simply with the password protected menu structure. The configuration of the alarm organization is very simply realized with the integrated alarm matrix.
Technical Data:
Type of device: Analys 2016net; Power Supply: 24V DC; Max. Consumption: 25W; Temperature Range: -20°C to +50°C (short time 60°C); Analog-Output: 1x4-20mA (max. 250 ohms); Digital-Output: 4 Logic Signal for Alarm 1 to 4; 1 Logic Signal for Sensor Fault; 1 Logic Signal for Calibration Mode *; 1 Logic Signal for Calibration Status
1 Logic Signal for Maintenance Alarm; to activate the Solenoid Valve Unit; to activate the Presuction Pump Block; Network: TCP/IP RS232C, CAN Bus (in preparation); Remote Control: with TCP/IP
Data Pick Out: with FTP; Event Recorder: for max. 4000 Events
Temperature Recorder: for max. 4000 Events
* Note dew point of sampling Technical Data IR-Sensor:
Type of Gas: Methane CH4; Measuring Principle: ND-Infrared Detector; Measuring Range: 0-100% LEL; Reaction Time T90: < 10 seconds; Accuracy: 2% FS; Stability: < ± 1% / Month; Zero-Drift: < ± 1% / Month; Temperature Range: -20°C to +50°C (short time 60°C)
Relative Humidity: < 99% RH; Warm up Time: 1 hour

Electrical Connections:
Power Supply: 3 pole Plug; Interface: 2x37 pole Plug; RS232C: 1x9 pole Plug; CAN: 1x9 pole Plug; TCP/IP: 1x RJ45; Remote Control: with Web Interface; Housing Type: 19'' inch rack version; Painting: RAL 7035/5002; Type of Protection: IP30
Note: Analys 2000 that is replaced and 100% compatible with the new Analys 2016net (Tanguard 2000)