Euchner Vietnam, MGB-L0HE-APA-R-112600 (ORDER NO. 112600), Đại lý chính hãng Euchner Tại VietNam
MGB-L0HE-APA-R-112600 (ORDER NO. 112600)
Interlocking set MGB-L0HE-APA..., without controls or indicators, RC18, on mounting plates
- Interlocking (without guard locking)
- With plug connector RC18
- Mounted on mounting plates
- With escape release
- Unicode
Escape release MGB-E-A2-106051 (Order No. 106051)
Mechanical values and environment
Ambient temperature |
-20 ... +55 °C |
Installation orientation |
any |
Material |
|
Housing |
Die-cast zinc/stainless steel, powder-coated |
Mechanical life |
1 x 10⁶ |
Miscellaneous
Additional feature |
with mounting plate |
Product version number |
V2.0.0 |
Handle modules MGB-H-AA1A6-R-111838 (Order No. 111838)
Mechanical values and environment
Ambient temperature |
-20 ... +55 °C |
Degree of protection |
IP65 |
Installation orientation |
Door hinge DIN right |
Material |
|
Housing |
Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Additional feature |
with mounting plate and automatic lockout mechanism |
Product version number |
V3.0.0 |
Interlocking modules MGB-L0-APA-AA1A2-S1-R-112596 (Order No. 112596)
Controls and indicators
Electrical connection ratings
Degree of contamination (external, according to EN 60947-1) |
3 |
Discrepancy time |
|
between FO1A and FO1B |
max. 10 ms |
Rated impulse withstand voltage Uimp |
1.5 kV |
Rated insulation voltage Ui |
30 V |
Risk time according to EN 60947-5-3 |
max. 350 ms |
Safety class |
III |
Transponder coding |
Unicode |
Utilization category |
|
DC-13 |
24V 200mA |
|
Monitoring outputs OD, OT, OL, OI |
Output current |
max. 50 mA |
Output type |
Semiconductor outputs, p-switching, short circuit-proof |
Output voltage |
UA-2V ... UA V DC |
|
Safety outputs FO1A, FO1B |
Output current |
|
per safety output FO1A / FO1B |
1 ... 200 mA |
Output type |
Semiconductor outputs, p-switching, short circuit-proof |
Output voltage |
|
UFO1A /UFO1B HIGH |
UB-2V ... UB V DC |
UFO1A /UFO1B LOW |
0 ... 1 V DC |
Test pulse interval |
min. 100 ms |
Test pulses |
max. 0.3 ms |
|
Power supply UA |
Current consumption |
|
IUA |
max. 10 mA |
Operating voltage DC |
|
UA |
24 V DC -15% ... +10% |
|
Power supply UB |
Current consumption |
|
IUB |
max. 80 mA |
Operating voltage DC |
|
UB |
24 V DC -15% ... +10% |
Mechanical values and environment
Ambient temperature |
|
at UB = 24V DC |
-20 ... +55 °C |
Connection |
Plug connector RC18 |
Degree of protection |
IP65 |
Installation orientation |
Door hinge DIN right |
Material |
|
Housing |
Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel |
Mechanical life |
|
in case of use as door stop, and 1 Joule impact energy |
0.1 x 10⁶ |
|
1 x 10⁶ |
Switching frequency |
0.25 Hz |
Reliability values according to EN ISO 13849-1
Mission time |
20 y |
|
Monitoring of the guard position |
Category |
4 |
Performance Level |
PL e |
PFHd |
3.7 x 10-9 |
Miscellaneous
Additional feature |
Mounting plate |
Product version number |
V4.0.0 |